T5 PCI-EPP ConvErsIon ProCEdUrEs
4. PlaCE THE EPP assEMBly on a FlaT sUrFaCE. rEMovE and rETaIn THE sIx (6) sCrEws and nUTs THaT sECUrE THE EPP To
THE MoUnTIng BraCkET. rEMovE and rETaIn THE CaBlE gUIdE. THE T5 PCI-EPP rEqUIrEs a nEw sPEd MoUnTIng BraCkET
(InClUdEd In THE kIT).
5. MoUnT THE nEw sPEd BraCkET To THE T5 PCI-EPP as sHown BElow. sECUrE wITH THE orIgInal sIx (6) sCrEws and nUTs
PrEvIoUsly rEMovEd. rEMEMBEr To rEInsTall THE CaBlE gUIdE on THE nEw sPEd MoUnTIng BraCkET
7. Make sure THE Two (2) orIgInal FUnCTIon kEy CaBlEs HavE BEEn Ty wraPPEd so THEy arE oUT oF THE way. MovE THE T5
PCI-EPP assEMBly (sTEP 5) BaCk To THE UnIT. PlUg THE CoMBInEd, sInglE ConnECTor For THE FUnCTIon kEys (InClUdIng
THE HEaTEr PowEr CaBlE IF a METal T5 PCI-EPP w/HEaTEr Is BEIng InsTallEd) InTo THE T5 PCI-EPP. rEConnECT THE
sPEd daTa CaBlE PrEvIoUsly rEMovEd (rj-45 ConnECTor End).
VEPP with mounting bracket
T5 PCI-EPP with new mounting bracket
Cable
guide
6. ConnECT THE nEw FUnCTIon kEy CaBlE Ends To THEIr rEsPECTIvE kEyPad PCBs. THE CaBlE Ends arE MarkEd “leFT” and
“righT”. drEss, BUndlE, and roUTE THE FUnCTIon kEy CaBlEs (InClUdIng THE HEaTEr PowEr CaBlE IF a METal T5 PCI-EPP
w/HEaTEr Is BEIng InsTallEd) so THEy Follow THE sPlIT FlEx TUBIng down To THE sPEd ConnECTor.
rEMEMBEr: CaBlE dEsIgnaTIons For THE FUnCTIon kEys arE rEFErEnCEd wHEn vIEwIng UnIT FroM THE FronT. rEFErEnCE
PlaCEMEnT oF ConnECTors wHEn vIEwIng FroM rEar oF THE ConTrol PanEl (rT2000). vIEw FIgUrE BElow.
8. TUrn THE assEMBly ovEr so THE kEyPad Is FaCIng UP . slIdE THE assEMBly BaCk InTo THE ConTrol PanEl and sECUrE By
PUllIng THE grEEn HandlE UP. rEFErEnCE sTEPs 3 and 2 For rEInsTallIng sPEd assEMBly.
9. slIdE THE dIsPEnsEr BaCk InTo THE CaBInET.
rEMEMBEr: THE FUnCTIon kEy CaBlE For THE METal T5 PCI-EPP w/HEaTEr Has an addITIonal Two (2) wIrEs (rEd
and BlaCk) For THE InTErnal HEaTEr. THE IndIvIdUal CaBlE THaT sUPPlIEs 12vdC To THE HEaTEr sHoUld BE ProPErly drEssEs
and roUTEd To THE PowEr sUPPly and PlUggEd InTo any 8-PIn ConnECTors. vIEw FIgUrEs aBovE.
METAL T5 PCI-EPP W/HEATER CONVERSIONS ONLY! Properly dress, and route THE IndIvIdUal 12vdC HEaTEr CaBlE
so IT Follows THE PowEr CaBlE BUndlE In THE sPlIT FlEx TUBIng To THE PowEr sUPPly. PlUg IT InTo any avaIlaBlE 8 PIn
ConnECTor.
Right
Left
RT Power cable bundle to
the power supply (including
the 12vdc heater cable to the
power supply if a Metal T5
PCI-EPP is installed