Owner Manual

10
TDM-100/150 TO NMD-50 CONVERSION PROCEDURES
4. Disconnect the power and communication (Comms) cables from the dispenser (Figure 9). Carefully cut any Ty wraps
that are securing the cables to the dispenser. Remove the cables from the cabinet. Remove the note and reject cassettes.
Using a phillips-head screwdriver, remove the four (4) or six (6) mounting screws that secure the dispenser to the
swivel platform (Figure 10). Remove the TDM dispenser mechanism.
Ferrite
Figure 10. Remove mounting screws.
Figure 9. Power and Comm cable disconnected.
6. Dispenser Slide Rail Hardware - With the tray extended out, use a phillips screwdriver to remove the screws (3 on
each side) that secure the slide rails to the mounting brackets (Figure 11). Remove the slide rails (with mounting tray
attached) from the cabinet.
7. Mounting Brackets - Using an 11/32" nut driver,
loosen the two (2) nuts that secure the brackets to the cabinet (Figure
11). Remove the brackets. These will be replaced. Start two (2) more nuts (one each side) to the third bolt closest to
rear of cabinet (Figure 12). Note: The cabinet ground wire is attached to the left side front bolt. You will have to
temporarily remove this nut to remove the ground wire lug. Nut will be attached in later steps.
Figure 11. Side rails removed.
Figure 12. Nuts started on bolts.
8. Tray Stop (Door) - Locate the tray stop mounted on the door (Figure 13).
Remove this item from the door using a 7/16" nut driver..
Figure 13. Remove tray stop.
Hex nuts
w/tooth
washer