VERIFICATION:
To verify that the conguration is complete and the modem can reach the
network, perform the following steps:
• Go to Management > Diagnostics > TCP/IP Wireless
• Verify the “Wireless IP Address” eld displays a valid TCP/IP address
• If no address is displayed, check the Error Code displayed and contact tech
support, 1.800.259.6672
To check the signal strength at the location:
• Go to Management > Diagnostics > TCP/IP Wireless
• Select “Disconnect” to disconnect from the network
• Select “Signal Strength” to verify the signal. The minimum acceptable
signal is 7 (seven), and that may be marginal. Moving the antenna may increase
efciency. Push “Signal Strength” again to see new level.
• Select “Connect” to reconnect to the network. The IP address should
reappear.
To test communications to the host/processor:
• Go to Management > Diagnostics > Modem/Ethernet > Test
• Press F8 key (bottom right screen key) to display virtual keyboard
• Enter the host name (from Terminal Conguration > Communications > Host
Address)
• Press ENTER to test connection to host
If a weak signal is encountered, and does not improve, it may be necessary
to obtain the booster amplier. The amplier installs between the TDL
Gateway and the antenna, and requires AC power. It increases both the
Transmit and Receive signals. Contact Triton Technical Support for fur-
ther details. 1.800.259.6672
The release notes for the software service packs listed in the front of this instruction
are attached. Please read them carefully.
ERROR CODES:
608 Phonebook entry is unavailable reinstall driver update le.
619 Port disconnected.
633 Modem disconnected, modem off or in use
666 Device not ready; device or modem is not functioning
679 No signal strength; antennae disconnected.
Return the ATM to service and perform a balance inquiry or withdrawal to verify
operation.