Owner Manual
1-3
RL1600 AND RL2300 SHALLOW CABINET WITH MM
BEFORE PROCEEDING:
• Ensure all of your Journal Records have been saved to a USB device.
• Perform a proper management function shut down to remove power from the ATM.
• Unlock and open the ATM control panel. Turn the power switch to the OFF (0) position. If possible,
unplug the ATM power cord at the wall outlet.
• Open the dispenser area.
1. Disconnect the dispenser communications and power cables from the dispenser. Unplug the dispenser
power cable from the power supply and remove from the unit. Set aside for reinstallation.
2. Refer to the applicable service manual for your unit for steps to remove your dispenser. Removal of
the dispenser will provide the working room necessary to accomplish the cable routing.
3. Disconnect the security module communication cable and the power cable from the security module
and feed the cable into the upper cabinet.
4. Connect the dispenser communication cable to the security module. Tighten the thumbscrews to secure
the cable.