Owner Manual

3-10
HOLE CLOSEOUT BRACKET KIT
Cabinet # 03015-00052 & 03015-00167 with an NMD 50 Dispenser
**If the unit has been upgraded, skip to step #7.
5. Route the security module power cable and
security module communications cable past
the back opening (green circle) and through
the upper left cable clips. Route the cables
into the upper portion of the cabinet through
the left hole opening.
6. Obtain the dispenser power cable. Plug the
power cable into the unit’s power supply in the
upper portion of the cabinet. Route the cable
through the left hole opening into the lower
cabinet.
7. Install the 6 bolts into one closeout bracket.
Set the closeout bracket in place into the right
opening. Install 6 more bolts into another
closeout bracket. Set the second closeout
bracket into the back opening as shown. Ensure
the bolts and brackets are sitting at on the
upper cabinet.