10. Repeat steps for remaining cassettes.
11. Continue with Cassette Close or other procedure via Management Functions.
**Note**
Do not remove the reject cassette without removing the rejected notes. Removing reject cassette with power
applied causes the terminal to reset the reject count to zero. To ensure an accurate rejected note count, remove
notes from reject bin every time it is removed from dispenser.
     
**Note**
Do not remove the reject cassette without removing the rejected notes. Removing reject cassette with power
applied causes the terminal to reset the reject count to zero. To ensure an accurate rejected note count, remove
notes from reject bin every time it is removed from dispenser.
1. While security cabinet is open, remove the reject bin by grasping the handle and pulling from dispenser.
2. If applicable, unlock cassette with key, then open lid.
3. Empty rejected notes.
4. Close cassette lid. If applicable, lock cassette with key.
5. Using handle, slide the cassette into the dispensing mechanism. Make sure cassette is seated rmly.
 
is function dispenses notes from each operational cassette into the reject cassette. No notes are sent to exit.
1. Navigate to Management Functions > Diagnostics > Dispenser.
2. Press Test Dispense.
3. Press desired single cassette or All Cassettes to begin the test dispense operation. A pop-up dialog will in-
form user if test dispense was successful.