Guide
Triton Systems ©
5
e electronic lock combination consists of six digits. Upon arrival, the combination is set at the factory de-
fault
setting of 1-2-3-4-5-6. To open electronic lock, follow the steps below:
**Note**
Aer each key press, the lock will beep. Aer the nal digit is entered, the lock will beep twice and the 4-second
open period will begin.
1. Enter the six-digit combination. If successfully entered, the lock will beep twice.
2. Aer lock is opened, the door may be opened. Open door by liing up on the lever under the tab on the
vault door. e bolt will retract when door is opened on the swing bolt style lock.
Invalid code entry - Lock will beep three times if combination is entered incorrectly. Repeat steps 1 - 2.
e electronic lock combination consists of six digits. Upon arrival, the combination is set at the factory de-
fault
setting of 1-2-3-4-5-6. To open electronic lock, follow the steps below:
**Note**
Aer each key press, the lock will beep. Aer the nal digit is entered, the lock will beep twice and the 4-second
open period will begin.
1. Enter the six-digit combination. If successfully entered, the lock will beep twice.
2. Turn the outer dial clockwise to the open position within four seconds.
3. Aer lock is opened, the door may be opened.
Invalid code entry - Lock will beep three times if combination is entered incorrectly. Repeat steps 1 - 3.
1. When prompted via Management Functions, remove cassette by grasping handle and pulling from dis-
penser.
2. If cassette has a lock, use the security key to unlock cassette.
3. Open cassette by simultaneously pressing the green release button and liing the lid. Flip lid back com-
pletely, allowing it to rest on at surface.
4. Pull the packer plate to the front of the cassette (toward the handle). Ensure the packer plate is fully back.
Maintain pressure on the packer plate as needed while loading notes. Refer to the sticker located on the
inside cover of cassette for loading instructions.