Owner Manual
1A-4
EJ TO SECURITY MODULE UPGRADE PROCEDURES
RL5000 UPGRADE
BEFORE PROCEEDING:
• Ensure all of your Journal Records have been saved to a USB fl ash drive.
• Perform a proper management function shut down to remove power from the ATM.
• Unlock and open the ATM control panel. Turn the power switch to the OFF (0) position. If possible,
unplug the ATM power cord at the wall outlet.
• Open the dispenser area.
1. Refer to the applicable service manual for your unit for steps to remove your dispenser. Removal of
the dispenser will provide the working room necessary to accomplish the upgrade.
2. Disconnect the dispenser communications and power cables from the dispenser. Loosen the four wire
plate cable clips securing the control panel cables. Unplug the dispenser communication from the
mainboard and the dispenser power cable from the power supply and remove from the unit. Set aside
for reinstallation.
3. Disconnect the dispenser to EJ cable and remove the cable. Discard cable.
4. Disconnect the EJ to docking board or mainboard cable as applicable and remove the cable. Discard.
5. Remove the hardware attaching the EJ to the side or rear of the cabinet and remove the EJ. Discard.
7. Connect the security module power cable and
communications cable to the new security
module as shown.
Removal
Installation
6. Connect the new dispenser communication cable to the new security module. Tighten the thumbscrews to
secure the cable.
Communication
Power