ARGO Quick Reference Guide THIS AREA FOR SERVICE PROVIDER CONTACT INFORMATION: TDN 07103-00229 08/2013
MANAGEMENT FUNCTIONS - Access Instructions 1. At ATM Welcome Screen, press and hold down the key (Lower-right corner of keypad), press <1> key, then release both keys. The Top menu will be displayed. 2. At the Top menu, select Management Functions option. Enter password and select . The Management Functions MAIN MENU is displayed. RESTART / SHUTDOWN TERMINAL Follow Access Instructions to enter Management Functions. Select SYSTEM PARAMETERS.
CLOSE FUNCTIONS Follow Access instructions to enter Management Functions. Select TERMINAL CLOSE FUNCTIONS. DAY CLOSE: This option is used to complete daily balancing of the ATM with the processor. Totals are cleared and switched to the next business day. TRIAL CLOSE: T his option functions like a Day Close except the totals are not cleared. JOURNAL FUNCTIONS Follow Access instructions to enter Management Functions. Select JOURNAL.
CASSETTE CLOSE FUNCTIONS Follow Access instructions to enter Management Functions. Select TERMINAL CLOSE FUNCTIONS. Select CASSETTE CLOSE. Select cassette(s) to Close. A check mark (√ ) identiPress . fies which cassette(s) are selected. After cassette(s) have been reinserted in the dis- penser, press . Note: If an NMD-50 dispenser is installed, wait for the cassettes to LOCK (this is done automatically). Press if applicable.
REPLENISH SCDU/HCDU CASSETTE STEP ACTION 1 Unlock/Open Cabinet security door. Open the Reject Bin door and remove any rejected notes. DO NOT recycle rejected notes! ACTION STEP 5 2 Remove Place currency in the cassette. Push the GREEN release lever and slowly push packer forward against the notes. the cash cassette by lifting slightly and pulling forward. open the lid. Unlock the cassette and 6 3 Pull the packer plate to the front of the cassette (towards the handle) until it locks.
REPLENISH SDD CASSETTE STEP 1 ACTION Unlock/Open dispenser security door . Grasp the cassette handle and remove the cassette. ACTION STEP 4 Lift the reject tray. Push the packer plate to rear of cassette 2 and latch in place. Cassette MUST BE PRIMED with the cassette key before inserting on o the loading tray. Insert key and turn clockwise to show GREEN indicator in window.
REPLENISH MINIMECH CASSETTE STEP ACTION 1 Unlock/Open dispenser security door. Grasp Tray handle and remove note cassette STEP 2 Remove ACTION 5 Place currency in the cassette. 6 Grasp the handle and slide the note cassette packer forwards against the notes. Slowly push any rejected notes from the reject compartment. DO NOT recycle rejected notes! 3 Move the pusher plate to the rear of the tray (towards the handle). 4 Count the number of bills that remain in the cassette, if any.
REPLENISH NMD-50 CASSETTE(S) STEP 1 ACTION Unlock/Open dispenser security door. Grasp cassette handle with one hand while holding mechanism with the other. Pull cassette out s l i g h t ly , then place one hand underneath. cassette. Remove STEP 5 ACTION Place currency in the cassette and move packer plate against 2 Press the green lid. Flip the lid a flat surface. the notes. release button and lift the back fully letting it rest on 6 Extend the “Pawls” on packer plate fully.
REPLENISH RECEIPT PAPER Note: This procedure requires terminal is powered up. STEP ACTION STEP 1 Open control panel. If paper remains on roll, cut or tear paper between roll and printer. 4 Install new paper roll onto spindle. 2 Press 5 Insert paper/spindle into paper bracket. Paper feeds from TOP of roll! 3 Remove spent paper roll and spindle from paper bracket. 6 Feed end of paper into printer take-up slot. Paper will feed automatically through the printer and slightly out front of unit.
COMBINATION LOCKS Introduction The security cabinet can be secured using either a mechanical or electronic combination lock. This page covers how to operate the combination of either lock. Operating the Mechanical Lock Unlocking the Lock There are two marks on the dial ring. The index at the top is used for opening the lock, The index 30 degrees to the left is used only when changing the combination. The dial should always be turned slowly and evenly.