manual

error Code desCripTion
110 Trailing edge timeout at exit
111 Diverter timeout
112 Timeout waiting for leading edge at reject
113 Timeout waiting for trailing edge at reject
114 Exit blocked during purge
115 Diverter timeout on purge
116 Motor fault
117 Timeout waiting for note to divert
118 Exit sensor blocked on start of dispense or learn
119 Diverter in dispense position on start of dispense or learn
121 Note cassette not present
122 Unexpected note at exit
123 Hardware error
124 Diverter moved to exit position during reject purge
125 Initial status check failed
126 Diverter moved to reject position during dispense
127 Jam in TDM extension
128 Error in reply from the dispenser mechanism
129 No response from the dispenser mechanism
130 Command not acknowledged by the dispenser mechanism
131 CTS (Clear To Send) line from the dispenser is not active
132 Status reports bad double detect in last dispense
133 +5 VDC not present on carrier detect
134 Exit blocked as reported by status check
135 Feed sensor blocked as reported by status check
136 Modem initialization failed
137 Print failure to journal
138 Printer failed while printing to the receipt printer
139 Printer controller not responding to commands
140 Timeout waiting for printer to be ready
141 Paper jam reported by the controller during status check
142 Dispenser returns bad command error
144 No reply from the electronic journal
145 Error in reply from the electronic journal
146 No reply from command to electronic journal
147 Error in reply from electronic journal
148 Write to electronic journal failed
149 Read from the electronic journal failed
150 Status command to journal failed
151 Electronic journal full
152 Electronic journal corrupt