MEDECO HIGH SECURITY CUSTOM LOCK INSTALLATION 9100 9600 9700 RL5000 RL2000 RT2000 FT5000 FT5000XP ARGO 07103-28209 JUNE 12, 2013 CORPORATE HEADQUARTERS: 21405 B Street Long Beach, MS 39560 Phone: (800) 259 6672 Fax: (228) 868 9445 COPYRIGHT NOTICE © 2012 Triton. All Rights Reserved. TRITON logo is a registered trademark of Triton Systems of Delaware.
MEDECO HIGH SECURITY LOCK INSTALLATION Document Updates August 3, 2012 September 18, 2012 June 12, 2013 Original page 7 washer use clarification Added ARGO PURPOSE This guide covers the steps for the installation of the high security Medeco key lock. The advantage of the high security lock is that the key is removable only in the locked position; and its unique design makes it more tamper proof.
LOCK REMOVAL ALL LOCKS CONTROL PANEL AND FASCIA Removal of the current lock assembly is the same for all cabinets, both the control panel and front fascia doors. The picture provided is generic to all removals. 1. Open the control panel or fascia door. Return the lock to the locked position. Leave the key in the lock to act as a handle. 2. Remove the 1 (one) bolt holding the latch cam, and remove the bolt, lock washer and latch cam.
MEDECO HIGH SECURITY LOCK INSTALLATION LOCK INSTALLATION ALL CONTROL PANELS 1. Position the lock as shown in the figure to the right. Note the “flats” of the lock body are on the left and right. The key is in the “locked” position. Turn key to the right to “unlock”. Return to the “locked” position. This can be verified by removing the key. Reinsert the key to act as a handle. 2. Remove the large nut, insert the lock into the control panel opening and reinstall the large nut. Tighten the nut.
LOCK INSTALLATION FASCIA PANELS 9100, 9600 Hasp part number 03011-05272 The lock will be installed in the same manner as the Control Panel. Orient the key in the lock horizontally in the locked position. Below are illustrations of the hasp installed in the locked position. Rotate the key clockwise to unlock the lock.
MEDECO HIGH SECURITY LOCK INSTALLATION 9700, RL1600, RL2000, RL5000, ARGO Hasp part number 03011-02099 1. The lock will be installed in the same manner as the Control Panel. Orient the key in the lock horizontally in the locked position, key on left, teeth facing right. NOTE: Once the lock body is installed into the door, the stop washer must be repositioned. 2. While holding the key, remove the small nut and lock washer. The stop washer should appear as the picture at the right. 3.
SPACER WASHER INSTALLATION 9600 RL5000 These units may require spacer washers installed behind the cabinet door lock bracket to properly align the bracket and hasp. Check lock hasp engagement to determine if washers are necessary. Remove the bolts retaining the bracket and place one washer behind each mounting bolt location. Test the alignment of the hasp and bracket.
MEDECO HIGH SECURITY LOCK INSTALLATION LOCK INSTALLATION RT2000 FT5000 FT5000XP CAM PART NUMBER 03011-01932 1. Open the rear cabinet door. Return the lock to the locked position, key vertical. Leave the key in the lock to act as a handle. 2. Remove the 1 (one) bolt holding the latch cam, and remove the bolt, lock washer and latch Bolt Washer cam. Retain the lock washer. Latch Cam 3. Remove the nut securing the lock, and remove the lock from the front. Nut 4.
5. Remove the nut from the end of the lock. Ensure the lock stop plate stays correctly positioned, and the tumbler mechanism does not come out the front. Lock Stop Plate 6. Install the latch cam, lock washer (retained from disassembly), and nut. Cam Washer Nut 7. Ensure all hardware is tight. Test the lock before closing the door. Observe that the key can only be removed when the door is locked.