manual
Triton Systems ©
52
1. Navigate to Management Functions > Diagnostics > Dispenser > Cassette Parameters.
2. Press Relearn Bill ickness. For some dispensing mechanisms, the rst time the dispenser is set up or a
new note cassette installed, the dispenser will enter a learning mode during which it learns the thickness of
notes loaded. is function may dispense and reject up to 15 notes into the reject cassette. is function is
used during normal operation when the dispenser experiences an abnormal amount of rejected notes.
3. Press All Cassettes Locked to toggle on (check mark) or o (no check mark). is option physically locks or
unlocks all cassettes in the dispenser chassis. (NMD only)
4. Press Retract Cash to toggle on (check mark) or o (no check mark). is option enables the dispenser to
retrieve or retract dispensed notes aer a certain amount of time if notes have not been retrieved (FT only).
5. Press Retract Delay. Use the on-screen numeric keypad to enter desired delay time in seconds. e value
must be between 30 seconds and 120 seconds. is option allows the user to set the amount of time the dis-
penser will wait before retracting notes le in the bill chute (FT/NMD only).
6. Press Cassette in Service to toggle on (check mark) or o (no check mark). is function places the active
cassette (shown under option 5) in or out of service.