the host before closing the connection. Using the on-screen numeric keypad, enter desired number of
seconds between 0 - 1000.
— Press Electronic Receipt Heartbeat Interval. is function determines the time interval between heart-
beat messages. Using the on-screen numeric keypad, enter desired number of minutes between 0 - 999.
— Press Enter Host Password. is function allows user to enter the password that will be used to authen-
ticate the ATM terminal to the electronic receipt host. Setting an incorrect password will cause commu-
nication failure. Press Enter at warning screen, then use on-screen keyboard to enter the host password.
Press Enter and Return to save entry and return to the previous screen.
— Press Test Host Connection. is function will connect to the host to verify communication. Press Enter
to initiate test connection.
7. Lotto Conguration. is option is currently unavailable.
8. Press Conguration Wizard. is wizard directs user through initial setup of the terminal. See the Congu-
ration Wizard chapter for more information.
9. Press More Options.
— Charity. Option currently unavailable.
— Cardless Host Cong. Option currently unavailable.
— Press Anti-Skim Cong to view or congure the anti-skim card reader. Anti-skim card readers use two
forms of detection techniques: dierential voltage and temperature corrected. Categories for both types
should be lled in.
— Press Metal Present Time (sec) for dierential voltage. is is the time for which metal must be
continuously detected to be considered a skimmer. Set to 0 seconds to disable.
— Press Metal Absent Time (sec) for dierential voltage. is is the time for which metal must be
continuously removed before terminal recognizes skimmer removed.
— Press Detection Voltage (mV) for dierential voltage. is is the voltage sensed by the metal detec-
tor by which any higher voltage is considered a skimmer.
— Warning Voltage (mV) for dierential voltage. Option currently unavailable.
— Press Metal Preset Time (sec) for temperature corrected. is is the time for which metal must be
continuously detected to be considered a skimmer. Set to 0 seconds to disable.
— Press Metal Absent Time (sec) for temperature corrected. is is the time for which metal must be
continuously removed before terminal recognizes skimmer removed.
— Press Detection Voltage (mV) for temperature corrected. is is the voltage sensed by the metal
detector by which any higher voltage is considered a skimmer.
— Warning Voltage (mV) for temperature corrected. Option currently unavailable.