the host before closing the connection. Using the on-screen numeric keypad, enter desired number of
seconds between 0 - 1000.
Press Electronic Receipt Heartbeat Interval. is function determines the time interval between heart-
beat messages. Using the on-screen numeric keypad, enter desired number of minutes between 0 - 999.
Press Enter Host Password. is function allows user to enter the password that will be used to authen-
ticate the ATM terminal to the electronic receipt host. Setting an incorrect password will cause commu-
nication failure. Press Enter at warning screen, then use on-screen keyboard to enter the host password.
Press Enter and Return to save entry and return to the previous screen.
Press Test Host Connection. is function will connect to the host to verify communication. Press Enter
to initiate test connection.
7. Lotto Conguration. is option is currently unavailable.
8. Press Conguration Wizard. is wizard directs user through initial setup of the terminal. See the Congu-
ration Wizard chapter for more information.
9. Press More Options.
Charity. Option currently unavailable.
Cardless Host Cong. Option currently unavailable.
Press Anti-Skim Cong to view or congure the anti-skim card reader. Anti-skim card readers use two
forms of detection techniques: dierential voltage and temperature corrected. Categories for both types
should be lled in.
Press Metal Present Time (sec) for dierential voltage. is is the time for which metal must be
continuously detected to be considered a skimmer. Set to 0 seconds to disable.
Press Metal Absent Time (sec) for dierential voltage. is is the time for which metal must be
continuously removed before terminal recognizes skimmer removed.
Press Detection Voltage (mV) for dierential voltage. is is the voltage sensed by the metal detec-
tor by which any higher voltage is considered a skimmer.
Warning Voltage (mV) for dierential voltage. Option currently unavailable.
Press Metal Preset Time (sec) for temperature corrected. is is the time for which metal must be
continuously detected to be considered a skimmer. Set to 0 seconds to disable.
Press Metal Absent Time (sec) for temperature corrected. is is the time for which metal must be
continuously removed before terminal recognizes skimmer removed.
Press Detection Voltage (mV) for temperature corrected. is is the voltage sensed by the metal
detector by which any higher voltage is considered a skimmer.
Warning Voltage (mV) for temperature corrected. Option currently unavailable.