Repeated beeping during opening indicates that the battery is low and should be replaced. Triton recommends
replacing of the battery at least twice annually. e battery box is located on the inside of the vault/cabinet door
for straight deadbolt-style locks. Batteries for the swing bolt-style lock are behind the dial.
**Note**
For a straight deadbolt locks, if the lock will not operate (i.e. repeated beeping or no beeping) while the door is
closed and locked, the battery must be energized from the two external terminals on the front of the push-but-
ton panel. Battery contact must be maintained continuously via the external terminals to energize and open the
electronic lock. To energize the lock, connect a 9-volt alkaline battery on the external terminal points. While
maintaining contact, enter a valid combination and turn the dial clockwise to open the lock.
   -  
Caution
Test operation of electronic lock and combination several times with door open. If door locks and you do not
have access to the SMR (super master reset)password or the master password, lock will require drilling by a
licensed locksmith.
1. Open the vault door.
2. Remove battery box cover by pulling the front portion away from door.
3. Unsnap battery connector from top of battery, then remove old battery.
4. Connect new battery to battery connector, then install by pushing battery, connector, and wires up into bat-
tery box.
5. Reinstall battery box cover.
6. Test lock several times before closing the vault door.
   -  
Caution
is style of lock automatically locks when closed/latched. Test operation of electronic lock and combination
several times with door open. If door locks and you do not have access to the SMR (super master reset) password
or the master password, lock will require drilling by a licensed locksmith.
1. Grasp dial rmly, and push up 1/4 in. to dislodge dial.
2. Remove dial from stando mounting bolts to expose battery compartment.
3. Remove old battery.
4. Press and hold zero (0) key for 10 seconds, then install new 9-volt battery.
5. Reinstall dial by placing on the stando mounting bolts, then rmly sliding down 1/4 in. Ensure no wires or
cables are trapped between the dial and the safe door. Pinched cables can result in a short circuit.
6. Test lock several times before closing the vault door.