FUNCTION: TEST DISPENSE
FACTORY DEFAULT: N/A
A
CCESS INSTRUCTIONS:
1.) Select DIAGNOSTICS from
the MANAGEMENT FUNC-
TIONS screen.
2.) Select the TEST DISPENSE
option.
D
ESCRIPTION:
NOTE: The diagnostics options do not have a time-out associated with them.
You must manually exit the diagnostics mode when you are finished. This
command instructs the dispensing mechanism to dispense one note from the
cassette into the reject box. This test exercises the dispenser without sending
notes out the exit. A return code of ‘20 20 21’ indicates a successful test
dispense. Press the cancel key to return to the diagnostics menu.
E
RROR CONDITIONS:
If any code other than ‘20 20 21’ is displayed contact your service provider
for assistance.