manual
MODEL 91XX/97XX CONFIGURATION MANUAL
40
FUNCTION: TRIAL CASSETTE CLOSE
(9750)
F
ACTORY DEFAULT: N/A
ACCESS INSTRUCTIONS:
1.) Select CLOSE from the MAN-
AGEMENT FUNCTION screen.
2.) Select CASSETTE CLOSE.
Choose a cassette (A, B, C, or D).
3.) Select TRIAL CASSETTE
CLOSE.
D
ESCRIPTION:
Selecting this function prints a receipt summarizing activity on the cassette since the
last CASSETTE CLOSE was performed. The totals are not cleared (set to zero) or
reported to the host during a trial cassette close.
The following information is provided:
1.) START. Includes the starting quantity of notes in the cassette, and the total value
of this quantity.
2.) DISPENSED. Shows the number of
notes that have been dispensed and
the value of this quantity of notes.
3.) REMAINING. Shows the number of
notes remaining in the cassette, and
the total value of these notes.
4.) VALUE OF EACH DOC. The
denomination of the notes in the
cassette.
5.) TRANSACTIONS. The number
of transactions that have occurred
since the last.
6.) REJECTS. The number of reject
events. Rejects can involve more
than a single note per event.
E
RROR CONDITIONS:
There are no error conditions directly
associated with this function.
Sample TRIAL CASSETTE CLOSE
THIS COMMAND IS USED IN THE:
9100 9110 9700 9705 9710
9750