manual
MODEL 91XX/97XX CONFIGURATION MANUAL
194
FUNCTION: PRIMARY ALARM NUM-
BER
FACTORY DEFAULT: NONE
ACCESS INSTRUCTIONS:
1.) Select TERMINAL CONFIGU-
RATION from the MANAGE-
MENT FUNCTIONS menu.
2.) Select SET TERMINAL PA-
RAMETERS.
3.) Choose MORE.
4.) Select TRITON CONNECT.
5.) Select ALARM NUMBERS.
6.) Choose PRIMARY.
D
ESCRIPTION:
The PRIMARY ALARM NUMBER function is used to enter the telephone
number that the terminal can use for calling a Triton Connect Host Computer
to report alarm conditions.
NOTE: If no primary alarm number is entered, the terminal will default to
the PRIMARY TRITON CONNECT NUMBER when placing alarm-initi-
ated calls.
When this function is selected, the current phone number is displayed (if
nothing appears on the screen, no number is set). Select CHANGE to blank
the current entry, and then enter the desired phone number. The phone
number may be up to 30 digits long. It can also contain a dialing prefix,
such as a ‘9’ for an outside line, if necessary. If you need to pause after the
prefix, place a comma in the number for a two-second delay at that point.
Pressing the <BLUE> key first, then the <0> key, followed by the <RIGHT
ARROW> key to select the comma character. Make sure to enter the long
distance prefix ‘1’ if you are dialing an 800 number or a toll long distance
number. Do not enter dashes in the number.
E
RROR CONDITIONS:
There are no error conditions directly associated with this function.
THIS COMMAND IS USED IN THE:
9100 9110 9700 9705 9710
9750