FUNCTION: BACKUP NUMBER
FACTORY DEFAULT: NONE
A
CCESS INSTRUCTIONS:
1.) Select TERMINAL CONFIGU-
RATION from the MANAGE-
MENT FUNCTIONS menu.
2.) Select SET TERMINAL PA-
RAMETERS.
3.) Choose MORE.
4.) Select TRITON CONNECT.
5.) Choose BACKUP NUMBER.
D
ESCRIPTION:
The BACKUP NUMBER function is used to enter a backup number that the
terminal can use for calling back the Triton Connect computer.
When this function is selected, the current phone number is displayed (if
nothing appears on the screen, no number is set). Select CHANGE to blank
the current entry, and then enter the desired phone number. The phone num-
ber may be up to 30 digits long. It can also contain a dialing prefix, such as
a ‘9’ for an outside line, if necessary. If you need to pause after the prefix,
place a comma in the number for a two-second delay at that point. Press the
<BLUE> key, then the <0> key, followed by the <RIGHT ARROW> key
to select the comma character. Make sure to enter the long distance prefix
‘1’ if you are dialing an 800 number or a toll long distance number. Do not
enter dashes in the number.
E
RROR CONDITIONS:
There are no error conditions directly associated with this function.
THIS COMMAND IS USED IN THE:
9100 9110 9700 9705 9710