manual

MODEL 91XX/97XX CONFIGURATION MANUAL
186
FUNCTION: RESET/TEST MODEM
FACTORY DEFAULT: N/A
A
CCESS INSTRUCTIONS:
1.) Select TERMINAL CONFIGU-
RATION from the MANAGE-
MENT FUNCTIONS menu.
2.) Select SET TERMINAL PA-
RAMETERS.
3.) Select TELEPHONE.
4.) Select the MODEM SETUP
option.
5.) Select RESET/TEST MO-
DEM.
D
ESCRIPTION:
This function is used to reset and test
the internal modem. It should be run
after setting any of the modem con-
figuration parameters to make sure
an error was not made. It MUST be
run after changing the DIAL MODE
or DIAL RATE, otherwise these new values will not take effect until the
unit is turned off and back on again.
At the conclusion of the test a screen will appear indicating that the MODEM
CONFIGURED AND TESTED OK.
E
RROR CONDITIONS:
An error message will indicate a problem if the setup string is invalid or the
modem is not responding.
THIS COMMAND IS USED IN THE:
9100 9110 9700 9705 9710
9750