manual
MANAGEMENT FUNCTIONS
149
*NOTE*
The MAC MASTER KEY must be entered before the MAC Working
key. Likewise, the PIN MASTER KEY must be entered before the
PIN Working key.
FUNCTION: KEY MANAGEMENT
FACTORY DEFAULT: N/A
ACCESS INSTRUCTIONS:
1. Select TERMINAL CONFIGU-
RATION from the MANAGE-
MENT FUNCTIONS menu.
2. Select SET TERMINAL PA-
RAMETERS.
3. Choose the KEY MANAGE-
MENT option.
D
ESCRIPTION:
The KEY MANAGEMENT function provides access to Cash Dispenser
functions that control the method of entry for the MAC Master Key, MAC
Working Key, PIN Master Key and downloading the PIN working Key. The
functions accessed through this menu are listed below:
1. ENTER MAC MASTER KEY
2. ENTER PIN MASTER KEY
3. INJECT MASTER KEYS
4. ENTER MAC WORKING KEY
5. DOWNLOAD WORKING KEYS
E
RROR CONDITIONS:
The MAC Master Key must be entered before the MAC Working key. Like-
wise, the PIN Master Key must be entered before the PIN Working Key.
THIS COMMAND IS USED IN THE:
9100 9110 9700 9705 9710
9750