manual

MODEL 91XX/97XX CONFIGURATION MANUAL
136
FUNCTION: RELEARN BILL THICK-
NESS (9750)
F
ACTORY DEFAULT: N/A
A
CCESS INSTRUCTIONS:
1.) Select TERMINAL CONFIGU-
RATION from the MANAGE-
MENT FUNCTIONS menu.
2.) Select SET TERMINAL PA-
RAMETERS.
3.) Select CASSETTE SETUP.
4.) Choose the RELEARN BILL
THICKNESS option.
D
ESCRIPTION:
The first time the dispenser is set
up, or if a new Note Cassette is
installed, the mechanism will au-
tomatically enter a learning mode,
during which it will learn the thick-
ness of the currency or other media.
During this process the unit will
dispense and reject as many as 7-
15 notes. For multiple cassettes the
number of test rejects could almost
fill the single-note compartment of
the Reject Cassette. In such cases,
it is recommended that you remove
any rejected notes from the unit
before placing the Cash Dispenser
back into service.
It some instances (excessive number
of rejects during normal operation,
for example) it may be necessary to
manually initiate this process. The
RELEARN BILL THICKNESS
function enables you to force the dispenser to enter the learning mode.
Note that the operation affects ALL cassettes in the dispenser! The following
screens will be displayed as a result of a successful operation:
E
RROR CONDITIONS:
There are no errors directly associated with this function.
THIS COMMAND IS USED IN THE:
9100 9110 9700 9705 9710
9750