manual

MODEL 91XX/97XX CONFIGURATION MANUAL
132
FUNCTION: MULTIPLE AMOUNT
FACTORY DEFAULT: ‘$0.00’
A
CCESS INSTRUCTIONS:
1.) Select TERMINAL CONFIGU-
RATION from the MANAGE-
MENT FUNCTIONS menu.
2.) Select SET TERMINAL PA-
RAMETERS.
3.) Select CASSETTE SETUP.
4.) Choose the MULTIPLE AMOUNT option.
D
ESCRIPTION:
The MULTIPLE AMOUNT must be set in the Cash Dispenser before any
transactions can be processed. This number is the denomination of the cur-
rency installed in the currency cassette. It can be set to any value, as long
as this value is no less than 1/50th of the MAXIMUM AMOUNT. Typical
values might be 10, 20, 50, or 100.
Whenever a withdrawal transaction is performed, the amount entered or
selected is compared to the MULTIPLE AMOUNT. If the entry is not a
even multiple of this amount, an error warns the terminal user and displays
the current multiple amount.
E
RROR CONDITIONS:
If the MULTIPLE AMOUNT is not set correctly, the terminal will respond
by going into Configuration Error 186, BILL SIZE NOT CONFIGURED
CORRECTLY. To correct the error condition enter the management func-
tions and configure the bill size (MULTIPLE AMOUNT) to the size of the
bill in the cassette.
THIS COMMAND IS USED IN THE:
9100 9110 9700 9705 9710
9750