Owner Manual
3-5
9600
This section covers installing the jumper and connection of the optional
Triton external ethernet ModeM aSSeMBly (should you have one).
1. Pull the new Multi-function board out a few inches.
Install a jumper on J3 for 5 volts. (Top and middle
pins)
Failure to do this will cause
permanent damage to the modem
and multi-Function board!!!
2. Return the board and secure the tabs.
3. Connect the external modem cable to the AUX port
(Canadian example).
Ensure all connections are secure, all steps have been accomplished, and start your unit.
DON’T FORGET TO UPGRADE YOUR SOFTWARE: CANADA MUST USE THE
LATEST VERSION OF TRICOMM 2.1.22 TO LOAD THE EMV REQUIRED FILES.
NOTE: If you have an LED scrolling topper, you will be required to obtain an external power supply.
The new multifunction board will not provide power. The part number for a Triton approved power
supply is listed in the parts section. The current message will continue to scroll, but will no longer be
able to be changed from the ATM. To change the scrolling message, the originally provided remote
control must be used.