Owner Manual

7
FIELD CONVERSION PROCEDURE
10. Feed the other end of the dispenser DC power cable (and the ground wire if a TDM dispenser is installed)
down through the opening in the bottom of the top cabinet enclosure (the same one used for the AC line
cord and the dispenser communications cable).
11. Refer to the Figures below. Connect the DC power cable to the dispenser. If a TDM dispenser is installed,
plug the provided the ground wire to the existing spade connector on the dispenser.
12. Plug the new 6” AC extension cord into the power supply (make sure the AC line cord is plugged rmly
into the extension cord).
13. Plug the AC line cord into wall outlet.
14. Press AC power button on power supply to the ON (1) position and perform start up procedures.
15. Ensure all assemblies are operating correctly.
The ground strap connection at
the TDM dispenser.
TDM ground
strap
TDM power
cable
The DC power cable connection
at the TDM dispenser.
Mini-Mech
power cable
The DC power cable connection
at the Mini-Mech dispenser.
The Mini-Mech dispenser DC power cable
connection (10-pin connector) at the dual
power supply
The TDM dispenser DC power cable
connection (10-pin connector) at the
dual power supply
*** IMPORTANT***
The Mini-Mech DC power cable requires an in-line 4A
fuse. Before connecting a Mini-Mech DC power cable to the
dispenser, make sure the correct fuse is installed in the casing
and both ends of the cable are securely fastened. One fuse is
provided in the kit. There is no fuse in the provided cable.