Owner Manual
10
MODEL 9100 SPEECH UPGRADE
SOFTWARE DOWNLOAD
ACCESSING THE EPROM DIAGNOSTICS
The EPROM DIAGNOSTICS menu will be used to prepare the terminal for the
software download. To access the EPROM main menu you will need the EPROM
Access Code. Note: The factory default access code is ‘123456’. Remember to
change this code to prevent unauthorized access to the Eprom diagnostics!
1. While holding down the “1” key on the Terminal main keypad, reset the unit
by turning the AC Power Switch OFF for a few seconds, then back ON
again. The terminal will perform a series of boot-up diagnostics. At the
conclusion of the boot-up sequence the unit should now display a screen
requesting an EPROM access code. Release the “1” key.
2. Enter the EPROM access code. The unit will display an EPROM Diagnostics
menu:
3. Press the ERASE PROGRAM option. A warning screen is displayed:
DIAGNOSTICS
CHANGE PASS
ERASE PROGRAM
ERASE EEPROM
RESTART
DOWNLOAD
SET CON/VOL
* IMPORTANT *
The EPROM chip and all associated hardware required must be installed and
the EPROM must be erased prior to downloading the operating software
included in the kit. DO NOT load an update file over current Triton Standard
software running the machine.
The terminal software must be loaded using the TriComm for Windows®
executable program included on the Software CD (P/N 05200-00399). The following
procedures describe accessing the terminal Eprom Diagnostic screen and running
the TriComm for Windows program.