Owner Manual
10
TDM TO MINIMECH CONVERSION PROCEDURES
*** IMPORTANT***
The Mini-Mech DC power cable has an in-line 4A fuse (a spare
fuse is included in the kit). Before connecting a Mini-Mech
DC power cable to the dispenser, make sure the correct fuse is
installed in the casing and the fuse casing is securely fastened.
2. Place the MiniMech mounting bracket on the four (4)
standoff screws on the side of the cabinet. Notice the
rear slots are angled, and are inserted fi rst, then the
front is rotated down. The MiniMech retaining fi ngers
are to the rear.
Install the Mounting Bracket for the MiniMech
Bracket mounted to cabinet.
Fingers
3. Ensure the slots on the mount engage the screws.
Secure the four (4) nuts. Secure the door ground cable,
removed in an earlier step, to the front left screw and
nut.
Angled slot
Mounting screws, nuts installed
1. Start but do not tighten four (4) nuts (2 on each side)
on the sides of the cabinet.
4. Route the dispenser power cable and docking board
to EJ cable as shown. Place a black plastic cable
strain relief plug around each cable and press into the
dispenser mounting bracket. Route the power cable
from under the bracket to the back and over the top as
shown.
Dispenser power
cable
Docking board to
EJ cable