Installation Manual

Table Of Contents
Installation Procedures
3-16 © 1999 Triton Network Systems, Inc. All Rights Reserved.
3 Connect the jumpers to the front of the demarcation patch panel as shown
in Figure 3-7 ,Table 3-5, and Figure 3-8.
Table 3-4. Typical SONET OC-3 Demarcation Panel Input
Connections
Fiber Function
Fiber
Color
(Number)
Rear of
Demarcation
Panel
Fiber Type
IFU Alpha
Payload TX Slate (FA-1) 1A Single-mode
Payload RX White (FA-2) 1B Single-mode
OAM&P TX Green (FA-5) 2A Multi-mode
OAM&P RX Brown (FA-6) 2B Multi-mode
Interconnect TX Blue (FA-7) 3A Multi-mode
Interconnect RX Orange (FA-8) 3B Multi-mode
IFU Beta
Payload TX Slate (FB-1) 4A Single-mode
Payload RX White (FB-2) 4B Single-mode
OAM&P TX Green (FB-5) 5A Multi-mode
OAM&P RX Brown (FB-6) 5B Multi-mode
Interconnect TX Blue (FB-7) 6A Multi-mode
Interconnect RX Orange (FB-8) 6B Multi-mode