Mounting the IFU
Verify the correct IFU for location by checking the product number on the
IFU against the site drawing in the site engineering folder.
3 Refer to Figure 3-12 and position the IFU (2) on the mounting studs (7)
and engage the top clamp.
4 Install a snap ring (3) on each mounting stud (7).
CAUTION: Lifting hazard: Two people are required to
lift the Invisible Fiber unit. Grasp the Invisible Fiber
unit underneath the lower edge and lift with both hands.
To prevent injury, keep your back straight and lift with
your legs, not your back. To prevent damage to the
Invisible Fiber unit and components, never attempt to
lift the radio by the attached cables.
MISE EN GARDE : Danger de levage. Il faut deux
personnes pour soulever lunité Invisible Fiber
MD
. Saisir
lunité Invisible Fiber
MD
au-dessous du rebord inférieur,
puis soulever lunité avec les deux mains. Pour éviter les
lésions corporelles, garder le dos en position verticale et
soulever lunité en utilisant les jambes et non pas les reins.
Pour éviter lendommagement de lunité Invisible Fiber
MD
et de ses composants, ne jamais essayer de soulever la
radio en tirant sur les câbles qui y sont attachés.
CAUTION: Keep tools and parts away from walkways.
When carrying large, heavy equipment (such as the
Invisible Fiber unit), obstacles (such as hand tools,
cables or components) may not be easily visible and can
cause accidents.
MISE EN GARDE : Garder les outils et les pièces loin
des allées. Lorsquon transporte des équipements lourds et
à grandes dimensions (tels que lunité Invisible Fiber
MD
),
les obstacles (tels que les outils à main, les câbles ou les
composants) sont parfois difficiles à voir et peuvent causer
des accidents.