User's Manual
Output AC waveform
(AC mode)
Sine wave
Output AC waveform
(battery mode)
Pure Sine wave
INPUT
Rated input current
(at maximum load)
6.4A
Nominal Input
Voltage(s) Supported
200V AC; 220V AC; 230V AC; 240V AC
UPS input connection
type
C14 inlet
UPS input connection
description
IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall
receptacles
Input circuit breaker 10A
Phase Single-Phase
BATTERY
Full load runtime
(minutes)
4.5 min. (1200w)
Half load runtime
(minutes)
12 min. (600w)
Expandable battery
runtime
Extended runtime supported via optional external battery packs
External battery pack
compatibility
BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)
DC system voltage
(VDC)
48
Battery recharge rate
(included batteries)
Less than 6 hours from 10% to 80%
Replacement battery
cartridge (internal
UPS battery
replacement)
RBC94-2U
Battery Access Front panel battery access door
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Online, double-conversion power conditioning
Overvoltage
correction
2% output voltage regulation during overvoltages to 275
Undervoltage
correction
2% output voltage regulation during undervoltages to 156
Severe undervoltage
correction
2% output voltage regulation during undervoltages to 130 (under 70% load only)
LEDS ALARMS & SWITCHES
LED Indicators 14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery
and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in
rack/tower formats