Datasheet

Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SUDC208V84P
20-160kVA 3 Phase Power Distribution Center
Highlights
Full size Rack Power Distribution Cabinet supports 20-160kVA 3 phase UPS
power distribution in datacenter equipment racks
Two 42 pole breaker panels support 3 phase 208V and single phase 208V
and 120V output to connected equipment
Each breaker panel includes a pre-installed 225A 3 pole main breaker, ground
and neutral bars
Secure front and rear doors, removable side panels
Full line of accessories includes circuit breakers, corded receptacle whips and
PDUs
Description
Tripp Lite’s SUDC208V84P Power Distribution Cabinet supports 20-160kVA 3 phase UPS power distribution in critical datacenter equipment racks.
Full size rack enclosure with pre-installed 42 pole circuit breaker panel supports 3 phase 208V and single phase 208V and 120V output via optional
corded receptacle whips. Each breaker panel includes a 225A 3 pole main breaker, ground and neutral bars, plus 1/2 and 3/4 inch knockouts. Rack
enclosure offers secure front and rear doors, removable side panels and shares common dimensions and overhead wiring tray accessories as Tripp
Lite SR42UB rack enclosures. Front and rear doors enable access to front and rear facing breaker panels. Compatible with Tripp Lite SUBB-series
breakers, SUWL-series corded receptacle whips and a full line of compatible basic, metered, monitored and switched PDUs to support a variety of
advanced network configurations.
Features
SUDC208V84P Power Distribution Cabinet supports 20-160kVA 3 Phase UPS power distribution in critical datacenter equipment racks
Please consult the factory for UPS parallel capacity configuration support
Full size rack enclosure with two pre-installed 42 pole circuit panels support 3PH 208V and 1PH 208V and 120V via optional corded
receptacle whips
Line up and match power distribution cabinet blends with existing standard datacenter racks for an aesthetically pleasing appearance while
providing convenient connectivity between the centralized 3 phase UPS and protected electronic devices in equipment racks
Separately accessable front and rear breaker panels include 225A 3 pole main breaker, ground and neutral bars, 1/2 and 3/4 inch
knockouts (see Help & Downloads for manual with detailed wiring information)
Rack enclosure offers secure front and rear doors for access to each circuit panel, removable side panels and shares common dimensions
and overhead wiring tray and ladder accessories as Tripp Lite SR42UB equipment racks
Requires appropriate SUBB-series output circuit breakers (see Related Items for list of compatible SUBB breakers)
Optional SUWL-series cable whips and SUWEL-series extensions support a variety of connector types, voltages and cable lengths (see
Related Items for list of compatible SUWL-series and SUWEL-series cabling accessories)
Specifications
OVERVIEW
Model Type Cabinets
PHYSICAL
Shipping weight (lbs) 435

Summary of content (3 pages)