Datasheet

Voltage regulation
description
2% output voltage regulation in standard online, double-conversion mode
Overvoltage
correction
Corrects overvoltages up to 300V
Undervoltage
correction
Corrects undervoltages as low as 100V
LEDS ALARMS & SWITCHES
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options
Front panel LCD
display
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options;
LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN,
ITALIAN, SPANISH and PORTUGUESE (see manual)
Alarms Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel
operation
Alarm cancel switch
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and
execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module
replacement
SURGE / NOISE SUPPRESSION
UPS AC
suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Included mounting
accessory
description
4 sets of adjustable 4 post rack rails included
Installation form
factors supported
with optional
accessories
2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
Optional mounting
accessory notes
Qty 4 2POSTRMKITHD required; Qty 2 2-9USTAND required
Primary form factor Rackmount
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / inches)
5.14 x 17.5 x 25.82
UPS / Power Module
dimensions in
primary form factor
(height x width x
depth / cm)
13.1 x 44.5 x 65.6
Installed whole
system maximum
rack depth (inches)
32.5
Installed whole
system maximum
rack depth (cm)
82.6