Datasheet

BATTERY
Full load runtime
(minutes)
5 min. (1600w)
Half load runtime
(minutes)
13 min. (800w)
DC system voltage
(VDC)
48
Battery recharge rate
(included batteries)
Less than 4.5 hours from 10% to 90%
Replacement battery
cartridge (internal UPS
battery replacement)
RBC54
Battery Access Battery access door
Battery replacement
description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation
description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83V to
overvoltages to 145V
Overvoltage correction Input voltages between 127 and 145 are reduced by 12%
Undervoltage correction Input voltages between 96 and 108V are boosted by 12%
Severe undervoltage
correction
Input voltages between 83 and 95V are boosted by 24%
LEDS ALARMS & SWITCHES
LED Indicators 9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter
for load and battery charge level
Alarms Audible alarm indicates power failure and overload conditions
Alarm cancel operation Power-fail alarm can be silenced using alarm-cancel switch
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation
SURGE / NOISE SUPPRESSION
UPS AC suppression
joule rating
570
UPS AC suppression
response time
Instantaneous
EMI / RFI AC noise
suppression
Yes
PHYSICAL
Installation form factors
supported with included
accessories
Tower
Primary form factor Tower
UPS / Power Module
dimensions in primary
form factor (height x
width x depth / inches)
10.5 x 8.9 x 12.5