Specifications
IBAR12 IBAR12ULTRA IBAR12/20ULTRA
AC Energy Absorption (joules): 750 1200 1200
Surge Suppression (amp spikes)*: 60,000 96,000 96,000
UL 1449 Let-Through Rating: 400V 330V 330V
HF Noise Suppression (@ 1 MHz)
Filter Bank #1: 40 dB 40 dB 80 dB
Filter Bank #2: 80 dB 80 dB —
AC Receptacles: 2 NEMA 5-15R (front) 2 NEMA 5-15R (front) 2 NEMA 5-15R (front)
10 NEMA 5-15R (back) 10 NEMA 5-15R (back) 10 NEMA 5-15/20R (back)
AC Line Cord: 15', w/NEMA 5-15P plug 15', w/NEMA 5-15P plug 15', w/NEMA 5-20P plug
Circuit Breaker (Resettable): 15 amp 15 amp 20 amp
Dimensions (HxWxD, inches): 1¾ × 17½ × 4 1¾ × 17½ × 4 1¾ × 17½ × 4
Weight (lbs.): 5 5 5.4
IBAR12-20T RS-1215 RS-1215-20
AC Energy Absorption (joules): 1200 NONE NONE
Surge Suppression (amp spikes): 96,000 NONE NONE
UL 1449 Let-Through Rating: 330V — —
HF Noise Suppression (@ 1 MHz)
Filter Bank #1: 80 dB NONE NONE
Filter Bank #2: — NONE NONE
AC Receptacles: 2 NEMA 5-15R (front) 6 NEMA 5-15R (front) 6 NEMA 5-20R (front)
10 NEMA 5-15/20R (back) 6 NEMA 5-15R (back) 6 NEMA 5-20R (back)
AC Line Cord: 15', w/L5-20P plug 15', w/NEMA 5-15P plug 15', w/NEMA 5-20P plug
Circuit Breaker (Resettable): 20 amp 15 amp 20 amp
Dimensions (HxWxD, inches): 1¾ × 17½ × 4 1¾ × 17½ × 4 1¾ × 17½ × 4
Weight (lbs.): 5.4 5 5
RS-1215-RA RS-1215-HG DRS-1215
AC Energy Absorption (joules): NONE NONE 450
Surge Suppression (amp spikes): NONE NONE 36,000
UL 1449 Let-Through Rating: — — 330V
HF Noise Suppression (@ 1 MHz)
Filter Bank #1: NONE NONE NONE
Filter Bank #2: NONE NONE NONE
AC Receptacles:
6 NEMA 5-15R (front) 6 15A hospital grade (front) 6 NEMA 5-15R (front)
6 NEMA 5-15R (back) 6 15A hospital grade (back) 6 NEMA 5-15R (back)
AC Line Cord: 15', w/NEMA 5-15P plug 15', w/15A hospital grade plug 15', w/NEMA 5-15P plug
Circuit Breaker (Resettable): 15 amp 15 amp 15 amp
Dimensions (HxWxD, inches): 1¾ x 17½ x 4 1¾ x 17½ x 4 1¾ x 17½ x 4
Weight (lbs.): 5 5 5
RS-0615-R RS-0615-F
AC Energy Absorption (joules): NONE NONE
Surge Suppression (amp spikes): NONE NONE
UL 1449 Let-Through Rating: — —
HF Noise Suppression (@ 1 MHz)
Filter Bank #1: NONE NONE
Filter Bank #2: NONE NONE
AC Receptacles: 6 NEMA 5-15R (back) 6 NEMA 5-15R (front)
AC Line Cord: 15', w/NEMA 5-15P plug 15', w/NEMA 5-15P plug
Circuit Breaker (Resettable): 15 amp 15 amp
Dimensions (HxWxD, inches): 1¾ x 17½ x 4 1¾ x 17½ x 4
Weight (lbs.): 5 5
* Spike protection is provided in all three modes: hot to neutral, hot to ground and neutral to ground.
All Models: Nominal Input Voltage: 120VAC; Input Frequency: 50/60 Hz
All IBAR Models: Transient Response Time: Instantaneous (0 ns). Transient amplitude reduction occurs faster than the
clamp response of the varistors because of the high rejection rate of the ISOBAR filter networks.
UL 1449 (1999 rev.): IBAR12ULTRA, IBAR12/20ULTRA, IBAR12-20T and DRS-1215:
330V let-through (UL’s best rating for surge suppression); IBAR12: 400V let-through
UL 1283: All IBAR models, for line-noise filtering
CUL: meets Canadian National Standards as certified by UL
200112060 Isobar RM Metal Owner’s Manual 93-2028.qxd 1/3/02 2:48 PM Page 3