User Guide

OUTPUT
Frequency Compatibility 50 / 60 Hz
Output Receptacles (6) 5-15R
Output (Watts) 1800
Circuit Breaker (amps) 15
Right-Angle Outlets No
INPUT
Nominal Input Voltage(s) Supported 120V AC
Recommended Electrical Service 120V (110-125V)
Input Connection Type NEMA 5-15P input plug
Input Cord Length (ft.) 8
Input Cord Length (m) 2.44
Voltage Compatibility (VAC) 120
Maximum Surge Amps 84000
Right-Angle Plug No
USER INTERFACE, ALERTS & CONTROLS
Switches Includes 5 front panel switches - MASTER SWITCH controls all output receptacles (except the one marked
"unswitched"), INDIVIDUAL OUTLET switches control 4 individual output receptacles
Diagnostic LED Details PROTECTION PRESENT (green), GROUNDED (red), LOW OK (yellow) , MASTER(green), MONITOR, PRINTER,
AUX1 AND AUX2(blue)
SURGE / NOISE SUPPRESSION
AC Suppression Joule Rating 3150
AC Suppression Response Time NM = 0 ns. CM = <1 ns
Protection Modes Includes full normal mode (H-N) and common mode (N-G / H-G) line surge suppression
Clamping Voltage (RMS) 140
AC Suppression Surge Current
Rating
132,000 amps
AC Suppression Components Used Metal oxide varistors, toroidal balanced chokes and VHF capacitors
Safe Thermal Fusing Prevents unsafe conditions during extreme extended over-voltages and catastrophic occurrences
UL1449 Let Through Rating 330 L-G, 400 L-N, 400 N-G
IEEE587 Cat. A Ringwave Let-
Through
Less than 35 volts
EMI / RFI Filtering 40-80 dB
Immunity Conforms to IEE 587 / ANSI C62.41
3 / 5