Use and Care Manual

Setting accuracy
(20Hz~20MHz)
Voltage: <0.5% + 20mV
Current: <0.5% + 5mA
Ripple and noise
Voltage: 1mVrms
Current: 3mArms
Recall resolution
Voltage: 10mV
Current: 1mA
Temperature
coefficient
Voltage: 300ppm/ °C
Current: 300ppm/ °C
Instantaneous
response time
<100uS (50% load change, minimum load 0.5A)
Display
Display type
4-digit voltage and current LED display
Power
Voltage
AC 110V/220V± 5%
Frequency
50Hz/60Hz
Mechanical specifications
Dimensions(W*H*D)
105mm*155mm*210mm
Weight
3kg