User Manual
is shown. Pull the trigger to return to the normal operating mode. The
display (smaller digits lower right) will reflect the selected mode.
Backlight – ON/OFF
Press the trigger and release. Use the M button to step to the LitE display.
Press the SET button to select oN or oFF. Pull the trigger to return to the
normal operating mode.
Laser – ON/OFF
Pull the trigger and release. Use the M button to step to the LAS display.
Use the SET button to select oN or oFF. Pull the trigger to return to the
normal operating mode. When the laser is ON, the laser icon will
appear on the LCD.
HIGH Temperature Alarm Limit Setting
Pull the trigger and release. Use the M button to step to Alm H. Use the
arrow buttons to set the High Alarm limit. Press the SET button to turn the
High Alarm OFF. Pull the trigger to return to the normal operating mode. If
the high alarm limit is exceeded when taking measurements, the displayed
ALM H will blink and the alarm buzzer will sound (if ‘bU2’ is set to ON).
LOW Temperature Alarm Limit Setting
Pull the trigger and release. Use the M button to step to Alm L. Use the
arrow buttons to set the Low Alarm limit. Press the SET button to turn the
Low Alarm OFF. Pull the trigger to return to the normal operating mode. If
the low alarm limit is exceeded when taking measurements, the displayed
ALM L will blink.
Emissivity Setting
Pull the trigger and release. Use the M button to step to the icon. Use
the arrow buttons to adjust the emissivity (in 0.01 steps). The emissivity
range is 0.05 to 1.00. Pull the trigger to return to the normal operating
mode. For more information, see the Emissivity section.