Full Product Manual

Air Flow Measurements (CMM / CFM)
1. Turn on the meter using the ON/OFF button
2. Press the UNITS button to select the desired air flow
units: CMM (cubic meters per minute) or CFM (cubic
feet per minute). NOTE: At power up the meter will
display the last unit of measure previously entered.
3. To begin entering the area in m
2
or ft
2
, press and
hold the AREA button until it beeps twice. The
leftmost digit of the bottom display will begin to flash.
4. Place the sensor in the air stream. Ensure that the
air enters the vane as indicated by the arrow sticker
placed inside the vane. Refer to the diagram. The
large main LCD display shows the Air Velocity
reading. The upper right LCD sub-display shows the
temperature reading.
The meter has 2 memory locations (1 for CFM and 1 for CMM) that can be used
to store commonly used area sizes that you can recall at anytime.
1. Press the AREA button until meter beeps twice. A memory location
number will appear in the top right of the display indicating the memory
location.
2. Use the UNITS button to change the flashing digit
Use the MAX/MIN button to move the decimal
After all of the digits are entered, press and hold the AREA button (until
it beeps twice) to save the area into memory and return to CFM or CMM
measuring mode.
airflo
w
Arro
w
Side view of
Vane