LIST SUBNET:
To use the List Subnet function, IP and Mask should be set up, and the Subnet Mask should
be 24bits wide (subnet size of 256 devices, or 8 bits). Refer to the instructions on page 29 if
you need to update the IP, Subnet Mask, or Gateway.
While you are on the Network Tools screen, press Focus- to run the List Subnet function.
The Tester will then scan the whole subnet. Devices being scanned must reply, so the
discover rate is 100% if the device is operating normally. This List Subnet function will also
measure the network latency, and display it in ms (milliseconds).
The List Subnet display format is: XX-XX-XX-XX -XX-XX I.I.I.I N ms. Where XX is the MAC
address displayed in HEX, Iis the IP address displayed in decimal, and N is the network
latency.
Compared to the network sniff function, this function cannot detect devices with different
Subnet settings, but the same Subnet detection rate is 100%.
The List Subnet will take 1-10 seconds to finish. Press Focus- to exit the List Subnet
function.
PING TEST:
To use the Ping Test, IP, Subnet Mask, and Destination must be filled in. If the destination is
a domain, then DNS/Gateway are also needed. Refer to the instructions on page 29 if you
need to update the IP, Subnet Mask, or DNS/Gateway.
Use the Flip Keyboard when the destination section is yellow to edit the Destination.
While you are on the Network Tools screen, press Zoom+ to run the Ping Test.
The ping test displays result in chart form as shown on page 32. The first column is the
latency grade; the second column is the number of responses at that latency grade; the third
column is the respond time percentage; and the fourth column is the latency chart.