TRIPLETT Model 9325 True RMS AC/DC Clamp-On Meter Instruction Manual 84-898 7/11
Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present Double insulation SAFETY NOTES •Do not exceed the maximum allowable input range of any function •Do not apply voltage to meter when resistance function is selected. •Set the function switch OFF when the meter is not in use.
Remove the battery if the meter is to be stored for long periods. Always discharge capacitors and remove power from the device under test before performing Diode, Resistance or Continuity tests. •Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty of connection to the recessed electrical contacts. Other means should be used to ensure that the terminals are not "live".
1.AC DC AC (alternating current) and DC (direct currrent) Minus sign 6000 count (0 to 5999) measurement reading with 61segments Analog Bargraph AutoRange mode Relative mode Diode test mode Audible Continuity Data Hold mode Units of measure list MAX/MIN mode Frequency/duty cycle mode 2. 3.8.8.8.8 4.AUTO 5.REL 6. 7. 8.HOLD 9.°C,°F, μ,m,V,A,K,M,Ω, 10.MAX MIN 11.
Specifications Function AC Current (50/60Hz) AC Current (400Hz) DC Current DC Voltage AC Voltage (50-400Hz) Resistance Capacitance Range & Resolution 600.0 AAC 1000 AAC 600.0 AAC 1000 AAC 600.0 ADC 1000 ADC 600.0 mVDC 6.000 VDC 60.00 VDC 600.0 VDC 6.000 VAC 60.00 VAC 600.0 VAC 600.0 Ω 6.000KΩ 60.00KΩ 600.0KΩ 6.000MΩ 60.00MΩ 40.00nF 400.0nF 4.000μF 40.00μF 400.0μF 4000μF 10-10kHz Frequency Sensitivity: 15Vrms Temp (type-K) -20.0°C to 760.0°C (probe accuracy -4.0°F to1400.
Clamp size Diode Test Continuity Check Low Battery Indication Overrange Indication Measurements Rate Input Impedance Display AC Current AC Voltage bandwidth Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Over voltage Battery Auto OFF Dimensions/Weight Safety Opening 1.5" (40mm) approx Test current of 0.3mA typical; Open circuit voltage 1.5V DC typical. Threshold <40Ω; Test current < 0.
Operation NOTICES: Read and understand all warning and precaution statements listed in the safety section of this operation manual prior to using this meter. Set the function select switch to the OFF position when the meter is not in use. AC/DC Current Measurements WARNING: Ensure that the test leads are disconnected from the meter before making current clamp measurements. 1.Set the Function switch to the 1000ADC,600ADC, 1000AAC or600AAC range. 2.
DC/AC Voltage Measurements 1.Insert the black test lead into the negative COM terminal and the red test lead into the positive V terminal. 2.Set the function switch to the V position. 3.Select AC or DC with the MODE button. 4.Connect the test leads in parallel to the circuit under test. 5.Read the voltage measurement on the LCD display. Resistance Measurements 1.Insert the black test lead into the negative COM terminal and the red test lead into the positive terminal. 2.
Capacitance Measurements WARNING: To avoid electric shock, disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements. Remove the batteries and unplug the line cords. 1.et the rotary function switch to the Ω CAP position. 2.Insert the black test lead banana plug into the negative (COM) jack. Insert the red test lead banana plug into the positive (V) jack. 3.Touch the test leads to the capacitor to be tested. 4.
5.Read the temperature in the display. The digital reading will indicate the proper decimal point and value. WARNING: To avoid electric shock, be sure the thermocouple has been removed before changing to another measurement function Non-Contact AC Voltage Measurements WARNING:Risk of Electrocution. Before use, always test the Voltage Detector on a known live circuit to verify proper operation 1.Touch the probe tip to the hot conductor or insert into the hot side of the electrical outlet. 2.
to normal operation. Note: The HOLD feature will activate when the Backlight is turned on. Press the HOLD key again to exit Hold. RANGE BUTTON When the meter is first turned on, it automatically goes into AutoRanging. This automatically selects the best range for the measurements being made and is generally the best mode for most measurements. For measurement situations requiring that a range be manually selected, perform the following: 1.Press the RANGE button.
Triplett Three Year Limited Warranty Triplett warrants instruments and test equipment manufactured by it to be free from defective material or workmanship and agrees to repair or replace such products which, under normal use and service, disclose the defect to be the fault of our manufacturing, with no charge within three years of the date of original purchase for parts and labor. If we are unable to repair or replace the product, we will make a refund of the purchase price.