User's Manual
The shutoff unit alignment reset is necessary in order to indicate the CLM™
HUB that the unit is in the “CLOSED” position and thus prevents the water from
passing through the pipe.
+ Actuator Shutoff unit alignment reset
1. Regardless of the shutoff mounting, whether parallel or perpendicular to the
water flow direction, align the slot on the top part of the shutoff motor stem
perpendicularly to the water flow direction. If the stem slot is parallel to the
water flow direction after the shutoff mounting, the shutoff has to be toggled
manually by pressing the unit button for 2 seconds.
3. Reset the shutoff unit alignment by pressing on the shutoff unit button for at
least 20 seconds. The RGB LED on the top part of the shutoff enclosure
should turn ON and remain GREEN so for 10 seconds after the successful
alignment reset.
4. Once the alignment is reset, toggle the shutoff unit to the “OPENED” position
manually by pressing on the button.
5. Enable passage of water in the main line and prevent leaks or drippings.
24