User's Manual

1. The system should not disconnect a re extinguishing line or a re sprinkler line.
2. Ensure easy access shut off unit in case it might be required for service.
3. The unit can be installed perpendicularly or in parallel with the pipe.
4. With the utilization of the locking pin, a comfortable shutoff disconnection should be
possible after installation.
5. Do not position shutoff units within metal cabinets.
6. The wireless, battery operated water Shutoff unit is installed on ISO5211 valve. It will
actuate whenever a risky event is identied or when manually requested by the user.
This actuator is mounted on a ISO5211 flange using 2 screws, provided with the
installation kit. It is IP68-rated, meaning that its enclosure is both dust and water tight
and can also be submerged into water.
+ Actuator Shutoff unit Warnings
+ Actuator Shutoff unit batteries insertion/replacement
For version 1.5, slide out the locking pin about
½” from the enclosure to allow the separation of
shut off unit enclosure parts. Remove the screws
attaching the bottom and the top shutoff enclosure
parts (use 3/32” or 2.5mm Allen wrench) and
install 4 x CR123 batteries into the compartment.
Assemble the enclosure and fasten the screws.
For version 2, use a Philips screwdriver to remove
the battery housing cover and replace the batteries.
v 1.5
v2
22