User's Manual
1. Installation and/or replacement of a battery should be performed
by authorized personnel.
2. The system should not disconnect a re extinguishing line or a re sprinkler line.
3. Locate the most suitable place for installation on the water line (as indicated
above.)
4. Shut down the water supply, using the main valve of the building or site.
5. Dismantle the water line connectors in a way that would leave a gap suitable
for installing the 3/4” valve.
6. Install the unit on the water line.
7. Should it be required to have a flexible water pipe for mounting the disconnection
unit on the wall, dismantle the base unit by removing 4 screws to replace it with
the appropriate base unit.
8. Mark the holes’ position on the wall, drill and attach 4 studs and screws.
9. Manual opening and closing of the valve handle should be possible after installation.
10. Enable passage of water in the main line and prevent leaks or drippings.
11. Ensure easy access to the battery housing (opened with a screwdriver) -
ensure a minimal access space of 30cm\1ft.
12. If unit wetting is probable, install an external protective casing.
+ Integrated Shutoff unit installation
18