User's Manual

147
Document Number: 0100SM1401 Issue: 12-16
Part H – Advanced
Alarm Group (Continued):
radioTxPowerAlarmTable .1.3.6.1.4.1.33302.30.5.14.0 Table Table of radio tx power alarms.
radioTxPowerAlarmState .1.3.6.1.4.1.33302.30.5.14.1.2.1 Integer Tx Power
Normal =Operating within normal conditions,
CriticalAlarm =Operating outside of specified
operating limits.
Recovered =Normal operating conditions
restored.
globalAlarmState .1.3.6.1.4.1.33302.30.5.15.0 Integer Global Monitored Alarm.
Normal =All monitored parameters are
operating within normal conditions,
UserAlarm =One or more monitored
parameters are operating outside of user
specified limits,
CriticalAlarm =One or more monitored
parameters are operating outside of factory
specified operating limits.
Recovered =One or more monitored
parameters had its normal operating
conditions restored.
txPllLocked .1.3.6.1.4.1.33302.30.5.17.0 Integer Transmit PLL lock status
radioFrequencyOffsetAlarmState
.1.3.6.1.4.1.33302.30.5.18.0 Integer Frequency error state.
Normal =Operating within normal conditions,
UserAlarm =Receive frequency error out of
user specified limits.
Recovered =Normal operating conditions
restored.
radioPllLockedAlarmState .1.3.6.1.4.1.33302.30.5.19.0 Integer Normal =Operating within normal conditions,
CriticalAlarm =Tx/Rx PLL failed to lock,
Recovered =Normal operating conditions
restored.
radioRssiCompareAlarmState .1.3.6.1.4.1.33302.30.5.20.0 Integer Normal =Operating within normal conditions,
UserAlarm =Rssi compared with paired unit
dropped below user specified limits,
Recovered =Normal operating conditions
restored.
radioGoodRxPacketAlarmState .1.3.6.1.4.1.33302.30.5.21.0 Integer Normal =Operating within normal conditions,
UserAlarm =Rx packet compared with paired
unit dropped below user specified limits,
Recovered =Normal operating conditions
restored.
ethernetLinkAlarmState .1.3.6.1.4.1.33302.30.5.22.0 Integer Normal =Operating within normal conditions,
UserAlarm =Ethernet link target unreachable,
Recovered =Normal operating conditions
restored.
resetAlarms .1.3.6.1.4.1.33302.30.5.100.0 Integer Read/Write Parameter
Reset alarms on current module.