User's Manual
132 Document Number: 0100SM1401 Issue: 12-16
Ease of Use
Part H – Advanced
Alarms
Introduction
The Q data radio can monitor the condition of various diagnostic and operating parameters (i.e DC volts, Tx Power, etc). The radio’s
active alarms can be evaluated by observing the event history and alarm states.
The alarm states can be viewed within the Monitoring section of the Web User Interface (Monitoring -> Alarms and Events).
Alarm States
Depending on active values of monitored alarms, the alarm states can be displayed in different levels of severities, including:
• Disabled: The alarm is not being monitored.
• Normal: The alarm value is in normal (acceptable) operating conditions.
• Recovered: The alarm has recovered from a warning or critical state, back into normal operating conditions, the alarm state
will remain in a recovered state, until either, the alarms are reset (by clicking the reset alarms button at the top corner of the
window) or the alarm state changes again.
• Warning: The alarm is within the warning threshold limits defined by the user.
• Critical: The alarm is outside of the hardware limits of the radio (alarms which can reach critical severity, can not be disabled).