User's Manual
Table Of Contents
- Part A – Preface
- Safety Information
- Revision History
- Important Information
- Compliance Information
- Part B – Feature Overview
- Introduction
- Features and Benefits
- Q Data Radio Range
- Part C – System Topologies & Operating Modes
- System Topologies
- Operating Modes
- Part D – Feature Detail
- Hardware
- Efficiency and Bandwidth
- Connectivity
- Ease of Use
- Security
- Part E – Radio Planning and Design
- Radio Path analysis
- BER & Fade Margin
- Radio Accessories
- RF Feeders and Protection
- Part F – Quick Reference Guide
- Introduction
- Half Duplex Radio - QR450
- Full Duplex Radio - QB450
- Hot Standby Half Duplex Radio - QP450
- Hot Standby Full Duplex Radio - QH450
- LED indicators
- Connecting Antennas
- Communication Ports
- Activating Transmitter
- Factory Default
- Digital I/O
- Connecting to Web User Interface (WUI)
- Resolving Ethernet Connection Issues
- Part G– Quick Start Guide
- Step-by-Step Point to Point Setup
- Step-by-Step eDiags Setup
- System Topology Configuration
- Serial and MODBUS
- Single Frequency (Simplex) Mode
- E-Series Emulation Mode
- Part H – Advanced
- Connectivity
- Ease of Use
- Security
- Part I – Installation & Commissioning
- Optimising the Antenna for Rx Signal
- Commissioning
- Part J – Firmware Updating and Maintenance
- Firmware Updating
- Global Firmware Updating
- Fuse Replacement - QR450
- Part K – Open Source License Acknowledgements
- Part L – Support Options
108 Document Number: 0100SM1401 Issue: 05-15
VSWR
Measurement taken Ratio
Subscriptions available SNMP Notifications, Alarm Output
Critical Alarm
Upper Critical Alarm limit 10:1
Warning Alarm
Default Warning Alarm Limit 3:1
Configurable Warning Alarm Limits 1.5:1, 2:1 or 3:1
Part H – Advanced
DC Supply
Units of measurement available DC Volts
State Change Hysteresis 0.5V DC
Subscriptions available SNMP Notifications, Alarm Output
Critical Alarm
Upper Critical Alarm Threshold 30V DC
Lower Critical Alarm Threshold 10V DC
Warning Alarm
Default Upper Warning Alarm Threshold 28V DC
Default Lower Warning Alarm Threshold 12V DC
Configurable Warning Alarm Threshold Range 10 to 30 V DC
Ethernet Link
The Ethernet link monitor will send pings to a user defined IP address. The radio can raise a
warning alarm, if a ping response is not received from the specified IP device.
Subscriptions available SNMP Notifications, Alarm Output
Warning Alarm
Primary IP The primary IP address to test
Secondary IP The secondary IP address to test
Fail Threshold
The number of failed pings allowed before
an alarm is raised
Retry Interval
The number of seconds to wait before
retrying a failed ping
Tx Power
Units of measurement available dBm
State Change Hysteresis 2 dBm
Subscriptions available SNMP Notifications
Warning Alarm
A warning alarm can be raised if the radio detects a Tx power level which is +/- 2dBm of the
target Tx power.
PLL Lock
A critical alarm can be raised if a PLL has been detected out of lock.
Subscriptions available SNMP Notifications, Alarm Output