Owner manual

Set Up Guide | Floor Scale
10
APPENDIX A: TROUBLESHOOTING AND
PERIODIC MAINTAINANCE
A.1 Troubleshooting Guide
Condition
Possible Problem & Correction
The system does not
operate No Display.
Power disconnected or bad power
supply: Check outlet first. Test the
AC adapter or power supply.
Indicator fuse blown: Replace
fuse, check for cause.
Interface Cable cut or
disconnected: Replace or Properly
repair cable.
Interface Cable wiring problem:
Check connections inside junction
box and at indicator.
Display stays at Zero.
Scale will not weigh
anything.
Item may be too light for scale
resolution.
Interface Cable cut or
disconnected: Replace or Properly
repair cable.
Interface Cable wiring problem:
Check connections inside junction
box and at indicator.
Load cell connections faulty:
Check load cell connections inside
junction box.
Debris under the scale platform:
Check and clean debris from
under the platform (Periodic
Maintenance).
Indicator faulty. Service or replace
indicator.