Instruction Manual

Operating Guide | TS-700 Series
2
Specifications
Resolution ......................... Display: 30,000
ADC................................... 2,000,000
Zero stability error .............. TK
0
< 0.1µV//K
Span stability error............. TK
spn
< ± 6 ppm//K
Sensitivity (internal) ........... 0. 3 µV /d
Input voltage ...................... -30~30mV DC
Excitation circuit................. 5 VDC
Load Cell Max.................... 8, 350Ω
AC power........................... AC100~250V
Operation temp.................. - 10 °C ~ + 40 °C
Operation humidity............. 90% RH
Storage temp ..................... - 40 °C ~ + 70 °C
KEYPAD KEYS
*requires adjustment of parameter settings
KEY
FUNCTION
On/Off
Powers on, powers of the indicator
Hold
Hold weight on scale, or Hold peak weight*,
or Hold unstable/animal weight*
Total
Total Weight: total of multiple weighings
Kg/lb
Display weight in pounds or kilograms
Gross/Tare
Tare container weight, display gross or net
weight
Zero
Returns the indicated weight to “0”
Print
Prints receipt (requires optional printer)
PC connectivity requires Triner Scale’s DataLog PC
software.