User’s Guide TS 700-MS Series 2 Full Function/Advanced Function Digital Indicator www.trinerscale.com Compatible with DataLog TM Scale-to-PC Data Logging Software UG Version 2.
Triner Scale & Mfg.Co., Inc. 8411 Hacks Cross Road Olive Branch, MS 38654 (800) 238-0152 www.trinerscale.com © 2011 Triner Scale. All rights reserved.
User’s Guide | TS-700 MS Table of Contents Specifications.................................... 2 Operation .......................................... 4 Load Cell Connections ...................... 7 Serial Port Connections .................... 8 Parameters and Settings................... 9 Data Output Formats ...................... 15 Using A Receipt Printer................... 18 Error Codes .................................... 19 Factory Default Settings..................
User’s Guide | TS-700 MS Specifications TECHNICAL PARAMETERS Resolution ...................... Display: 30,000 ADC ................................ 2,000,000 Zero stability error ........... TK0 < 0.1µV//K Span stability error .......... TKspn < ± 6 ppm//K Sensitivity (internal)......... 0. 3 µV /d Input voltage ................... -30~30mV DC Excitation circuit .............. 5 VDC Load Cell Max................. 8, 350 AC power ........................ AC100~250V Operation temp ...............
User’s Guide | TS-700 MS OVERVIEW Digital Readout/Display Enclosure Keypad Weighing Platform Quick Connect Socket AC Adapter Socket RS232 DB9 Socket (Printer, PC, Remote Display) 3
User’s Guide | TS-700 MS Operation KEYS AND THEIR FUNCTIONS KEY OPERATION / FUNCTION On/Off Press and hold for 2+ seconds to operate. Hold To Hold Weight on Scale (manual hold): With weight on scale, press Hold key. To Hold Peak Weight of Multiple Weighings (auto hold)*: To enable, press Hold key before loading scale. To Hold Weight of an Unstable Load (auto hold)*: To enable, press hold key before loading scale. To Release the Hold Function: Press hold key again to return to normal operation.
User’s Guide | TS-700 MS In settings mode: Return Key - Previous - Pressed with other key(s) for functions. Total To Add Weights: With weight on scale, press the Total key to place weight and count in memory. Remove weight, place next item on scale, press Total to add weight to total weight and total count. NOTE: To print totals, press and hold the Print key for 3 seconds while in View Totals mode (requires optional printer). To View Totals: Press Total and Print key at the same time.
User’s Guide | TS-700 MS Gross For use after a TARE weight has been stored in the indicator. Press key to toggle view between gross and net weight. PLEASE NOTE that there may be a momentary pause in the display when going from gross to tare weight. In settings mode: Right arrow key Press to move active digit one unit over to the right Tare With weight on the scale, press to Tare the weight. Press again to remove Tare weight. In settings mode: Down arrow key Press to reduce value of active (flashing) digit.
User’s Guide | TS-700 MS Load Cell Connections The indicator can connect with a maximum of eight (8) 350 load cells, 4 wire or 6 wire configurations. Excitation voltage for the load cell is 5VDC, the maximum output current is 120mA.
User’s Guide | TS-700 MS Serial Port Connection RS232 CONNECTOR The serial port connector is for attaching a peripheral device such as a printer or remote display, or for connecting the indicator to a PC. NOTE: PC interface requires specific software to be installed on the PC.
User’s Guide | TS-700 MS Parameters and Settings CAUTION: Use care when accessing and adjusting your indicator’s parameters. Several parameters can be accessed that, if altered, will change your indicator’s operations. TO ACCESS AND ADJUST THE TS-700 MS PARAMETERS: Press the PRINT and HOLD keys. “C” will display. Release the keys. “C08” will display, with the 8 flashing. The digit flashing is the active digit, and can be adjusted up or down* by using the ZERO/UP ARROW or TARE/DOWN ARROW key.
User’s Guide | TS-700 MS Use the right arrow key to move the active digit from the 1 to the 8 (the 8 will flash). Use the down arrow key to reduce the 8 to 6 (C16 will display). Press the PRINT ( ) key. The display will show digits for month, day and year. Use the arrow keys as discussed above to navigate to and change the digits. Press the PRINT ( settings. ) key to accept your Press the TOTAL ( ) key to exit.
User’s Guide | TS-700 MS C11 Hold function 0 = no hold function 1 = hold peak weight 2 = hold weight on scale 3 = hold animal weight 4 = reserved Note: hold peak weight shows the max. load of multiple weighings. C12 Kg/lb conversion 0 = kg/lb conversion disabled 1 = kg/lb conversion enabled C13 Upper/lower limit alarm Enter numeric values for upper and lower checkweighing limits. C14 Lower limit alarm value C15 Inner Code display Enter C15 to check the inner code.
User’s Guide | TS-700 MS C20 CAUTION: Changing these parameters will affect the indicator’s performance. Zero range (amount that can be zeroed out with the Zero key) C21 Zero range at power-up C22 CAUTION: Changing these parameters will effect the indicator’s performance. Automatic Zero: tracking range 0 = disable zero tracking 0.5 = ±0.5d 1.0 = ±1.0d 2.0 = ±2.0d 3.0 = ±3.0d 4.0 = ±4.0d 5.0 = ±5.0d Note: • d = division • The zero tracking range cannot be more than manual zero range.
User’s Guide | TS-700 MS C25 Negative display C26 CAUTION: Changing these parameters will affect the indicator’s performance. Standstill time C27 Standstill range 0 = -9d 10 = 10% max. capacity 20 = 20% max. capacity 50 = 50% max. capacity 100 = 100% max. capacity 0 = quick 1 = medium 2 = slow 1 = 1d 2 = 2d 5 = 5d 10 = 10d (d = division) C28 CAUTION: Changing these parameters will affect the indicator’s performance.
User’s Guide | TS-700 MS C32 RESERVED ------- C33 Relay output setting (optional) 0 = Close relay output 1 = Open relay output function 1 2 = Open relay output function 2 3 = Reserved menu C34 RESERVED ------- C35 RESERVED -------- C36 CAUTION: Changing these parameters will affect the indicator’s performance. Gravity of calibration location C36 = 9.7000 -- 9.9999 C37 CAUTION: Changing these parameters will affect the indicator’s performance.
User’s Guide | TS-700 MS Data Output Formats REMOTE DISPLAY FORMAT State A Bits: 0,1,2 0 1 2 1 0 0 0 1 0 1 1 1 0 0 Bits: 3,4 0 0 1 1 0 1 1 0 Decimal point position XXXXXX0 XXXXXXX XXXXX-X XXXX-XX XXX-XXX Division X1 X2 State B BITS FUNCTION Bits0 Gross = 0, net=1 Bits1 Symbol: positive = 0,negative =1 Bits2 Overload (or under zero)=1 Bits3 Dynamic = 1 Bits4 Unit: lb=0, kg=1 Bits5 Bits6 Constant 1 Constant 0 15
User’s Guide | TS-700 MS State C Bit1 0 0 1 Bit 3 Bit2 0 0 0 Bit0 0 1 0 Bit 4 Bit 5 Bit 6 unit Kg or lb g t printing=1 Extend display=1 Constant 1 Constant 0 PC COMPUTER CONTINUOUS SENDING FORMAT , S1 , S2 CR S3 Data S1: Weight status: ST = standstill US = not standstill OL = overload S2: Weight mode: GS = gross mode NT = net mode S3: Weight of positive and negative, “+” or ” –“ S4: “kg” or “lb” Data: Weight value, including decimal point CR: Carriage return LF: Line feed 16
User’s Guide | TS-700 MS SERIAL INTERFACE RECEPTION COMMAND RS232COM serial interface can receive simple ASCII command. Command word and role as follows: Command T Z P R Name TARE ZERO PRINT G.W/N.W Function Save and clear tare Zero gross weight Print the weight Read gross weight or net weight C Kg/lb Kg/lb conversion G G.W Check gross weight at net weight mode Data Format Print Format ID.NO...................004 (Serial No.) Date: ....................XX.XX. XX (yy.mm.dd) Time:...................
User’s Guide | TS-700 MS Using A Receipt Printer Print Key Typical receipt Cable to Weighing Platform Printer Connector To print receipts with an optional printer: - With power off, attach the printer cable to the connector socket on the underside of the indicator. - Power on the printer & indicator. - Place weight on the scale and press the Print key. - If receipt does not print, settings may need to be adjusted in parameters C18 & C19.
User’s Guide | TS-700 MS Error Codes ERROR CAUSE uuuuuu nnnnnn SOLUTION 1. Overloaded condition. 2. Wrong connection at load cell. 3. Load cell has quality problem. 1. Reduce the weight. 2. Check load cell connection 3. Inspect load cell. Check the input and output. 1. Calibration is incorrect. 2. Bad connections. 3. Load cell has quality problem. 1. Check scale is resisted or not, foot is kept level or not. 2. Check load cell connection. 3. Check input and output resistance of load cell.
User’s Guide | TS-700 MS Factory Default Settings PARAMETER INSTRUCTION DEFAULT C01 Calibration 1 C02 Decimal digits 0 C03 Resolution 1 C04 Max.
User’s Guide | TS-700 MS C23 Zero tracking time C24 C25 C26 C27 C28 C29 C30 C31 C32 C33 C34 C35 C36 C37 C38 C39 Overload range Negative range Standstill time Standstill range Dynamic filter Noise filter Print format Analog signal options 4~20mA testing Relay output setting Reserved Reserved Calibration location gravity Destination gravity Version No. check Reserved menu 21 1 9 10 1 2 0 2 0 1 4 1 0 6 9.7936 9.
Triner Scale & Manufacturing Co. Inc. 8411 Hacks Cross Road Olive Branch, MS 38654 (800) 238-0152 www.trinerscale.