User Manual

TMCM-3351 TMCL
Firmware Manual Firmware Version V1.11 | Document Revision V1.06 2019-APR-26
69 / 144
Binary Form of CALCVV SUB, 65, 42
Field Value
Target address 01
h
Instruction number 28
h
Type 01
h
Motor/Bank 41
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 00
h
Value (Byte 0) 2A
h
Checksum 95
h
Reply (Status=no error, value=0:
Field Value
Host address 02
h
Target address 01
h
Status 64
h
Instruction 28
h
Value (Byte 3) 00
h
Value (Byte 2) 00
h
Value (Byte 1) 00
h
Value (Byte 0) 00
h
Checksum 8F
h
©2019 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at www.trinamic.com