Number Axis Parameter Description Range [Units] Access
164 Disable fast
decay
comperator
See parameter 163. For classic const. o time
setting this parameter to 1 will disable current
comparator usage for termination of fast decay
cycle.
0/1 RW
165 Chopper
hysteresis end /
fast decay time
See parameter 163. For spread cycle chopper
mode this parameter will set / return the hys-
teresis end setting (hysteresis end value after a
number of decrements). For classic const. o
time chopper mode this parameter will set /
return the fast decay time.
0. . . 15 RW
166 Chopper
hysteresis start
/ sine wave
oset
See parameter 163. For spread cycle chopper
mode this parameter will set / return the Hys-
teresis start setting (please note that this value is
an oset to the hysteresis end value). For clas-
sic const. o time chopper mode this parameter
will set / return the sine wave oset.
0. . . 8 RW
167 Chopper o
time (TO)
The o time setting controls the minimum
chopper frequency. An o time within the range
of 5µs to 20µs will t.
O time setting for constant t O chopper:
N
CLK
= 12 + 32 tOF F (Minimum is 64 clocks)
Setting this parameter to zero completely dis-
ables all driver transistors and the motor can
free-wheel.
0. . . 15 RW
168 SmartEnergy
current
minimum
(SEIMIN)
Sets the lower motor current limit for CoolStep
operation by scaling the maximum current (see
axis parameter 6) value.
Minimum motor current:
0 -
1
2
of CS
1 -
1
4
of CS
0/1 RW
169 SmartEnergy
current down
step
Sets the number of StallGuard2 readings above
the upper threshold necessary for each current
decrement of the motor current. Number of
StallGuard2 measurements per decrement:
Scaling: 0. . . 3: 32, 8, 2, 1
0: slow decrement
3: fast decrement
0. . . 3 RW
170 SmartEnergy
hysteresis
Sets the distance between the lower and the
upper threshold for StallGuard2 reading. Above
the upper threshold the motor current becomes
decreased. Hysteresis: ([AP 172] + 1) 32
Upper StallGuard threshold: ([
AP
172]+[
AP
170]+
1) 32
0. . . 15 RW